+

Module de relais de retard numérique, 12V 220V, minuterie, mise sous/hors tension, interrupteur de retard réglable, Modification de voiture RT3

USD 3.38USD 5.37

Module de relais de retard numérique, 12V 220V, minuterie, mise sous/hors tension, interrupteur de retard réglable, Modification de voiture RT3

Description
Product selling point:1. Using high-quality materials, the quality is guaranteed2. High quality capacitors3. Standard industrial control terminal4. Simple and convenient to use5. Widely used in industrial control, electronic equipment control, household appliance control, intelligent application controlParameter:Specifications: 12V version--5.9*4.2*2cm; 220V version--6.2*4.8*2.3cmSupply voltage: 12V version - DC 7-12V; 220V version - AC 110-250VOutput terminal control voltage: DC 0-30V 8A; AC 0-230V 8A (the port has no voltage output by default)Working mode: trigger work, delay work, power-on delay, cycle delayKey functions and display operation instructions:K1 key: This key is the working mode switching key, and the working mode is divided into main mode and sub-mode.Main mode switching method: After long press the K1 button for 3s, the digital tube will display the current working mode such as ''P-1'', release the button at this time, if you want to select other modes, then briefly press K1 once and then release it, the ''P-2'' is displayed, thus switching to mode 2, there are a total of 5 main working modes. . After selecting the mode, press the K2 button again to confirm that the current mode is used as the working mode.Sub-mode switching method: when working normally and without timing, short press the K1 key once to switch the current sub-mode. It switches between these 3 modes every time it is pressed, and it automatically exits and enters the normal working state after displaying for 1s.K2 key: This key is used as confirmation key and shift key. When the main mode is selected, press the K2 key to confirm the selection and exit the main mode selection. . . . When the K2 key is pressed during normal operation or without timing, the digital tube will start to flash from the first digit on the left, indicating that the time can be adjusted at this time. Press the K2 key again to move to the second digit flashing to adjust the second digit. number, indicating that the current time can be adjusted.K3 key: This key is the time adjustment key and the decimal point (time unit) selection. When a digital tube flashes, it means that the time can be adjusted. At this time, press the K3 key, the number will increase, so that the time can be adjusted by adding and subtracting. . . When working normally and without timing, press the K3 key once, the decimal point will move to achieve unit switching.Description of working mode:P-1 main mode: the signal triggers the relay to pull in, the T1 time is up, the relay is disconnected, during operationP1.1: Re-triggering is invalid P1.2: Re-triggering and re-timing P1.3: Re-triggering the relay reset to terminate the timingP-2 main mode: signal trigger starts timing time T1, when the time is up, relay pull-in time T2 is disconnected (reset) P2.1: Re-trigger is invalid P2.2: Re-trigger re-timing P2.3: Re-trigger relay reset ends timingP-3 main mode: cyclic use: turn on T1, turn off T2, infinite loop. T1 and T2 time adjustableP3.1: The relay is turned on immediately after power-on—P3.2: The relay is turned off by default after power-onP-4 main mode: there is a signal, the relay is closed, the relay is kept closed, the signal disappears, the timing starts, the time is up, the relay is disconnected, during the delay period, the signal is given again, the delay is canceled, the relay is maintained, the signal disappears, and the restart timing. P-5 main mode: power-on delay on or off - power off to work againP5.1: The switch is closed after power-on, and the switch is disconnected after T1 time expiresP5.2: The switch is disconnected by default after power-on, and the switch is closed after T1 time expiresP5.3: The switch is disconnected by default after power-on, and the switch is automatically disconnected 0.5s after the T1 time expires.P5.4: After the power is turned on, the switch is closed for 0.5s and automatically disconnects. After T1 time expires, the switch is closed and automatically disconnected for 0.5sTime unit selection instructions:The time unit is switched to minutes or seconds using different positions of the decimal point, and the K3 key is used to modify the position of the decimal point, thereby realizing different unit switching.1. When the decimal point is behind the ten digits or there is no decimal point, the time unit is seconds; for example: 00.1 is 0.1 seconds2. When the decimal point is behind the single digit, the time unit is minutes; for example: 001. is 1 minuteInspection operation process:1. Turn on the power, press and hold the K1 button for about 3s to select the working mode, and then click the K2 button to confirm the mode2. Press the K3 key to select the time unit. When there is no decimal point or the decimal point is in the second place, the unit is seconds.When there is a decimal point on the far right, the unit is minutes3. Press the K2 key to enter the time setting and shift to select the time position to be adjusted4. When the digital tube is flashing, press the K3 key to add or subtract time. .5. After setting the time of each bit, click K2 and move it all the way to the far right to complete the setting.How to restore factory settings:1. Before turning on the power, keep pressing the K1 button and do not release it. At this time, turn on the power, keep pressing K1 for 2 seconds. 2. Release the K1 button, disconnect the power again, and then connect the power again to restore the initial settings. .Package Included:1* Delay relay module
Specification

is_customized : Yes

Application : Computer

Condition : New

Package : SMD

Brand Name : diymore

Origin : Mainland China

Type : Voltage Regulator

+