Relais à affichage numérique multifonction, interrupteur de synchronisation, Module de déclenchement à impulsion, Cycle marche-arrêt

USD 5.85USD 8.60

Relais à affichage numérique multifonction, interrupteur de synchronisation, Module de déclenchement à impulsion, Cycle marche-arrêt

Description

Multi-function digital display time relay 5V12V24V timing switch pulse trigger cycle on-off delay module

Function list: The function can be arbitrarily set by yourself when you buy it back, and the manual is provided; any parameters that can be set can be memorized when the power is turned off

PJ1: Jog (the signal relay is pulled in, the signal disappears and the relay stops)

PJ2: Self-locking (give a signal relay to pull in, and give a signal relay to stop)

PJ3: Give the signal, the relay will stop automatically for A second; the trigger is invalid during the delay period

PJ4: Give the signal, the relay will stop automatically for A second; trigger re-time during the delay period

PJ5: Give the signal, the relay will stop automatically for A second; trigger the superposition timing during the delay period

PJ6: Give the signal, the relay will stop automatically for A second; trigger reset during the delay period

PJ7: Give the signal, the relay is closed, the input signal is disconnected, the power is turned off after starting the timing A second, the signal is kept output again during the delay period, and the timing stops

After the PJ& is energized, the relay will pull in immediately, and the power will be turned off after a delay of A seconds; until the next power on

P・21: Give the signal, after a delay of A seconds, the relay will close

P・22: Give the signal, after more than A seconds, the relay will pull in, the signal will disappear, and the relay will stop

P・23: After the signal disappears for more than A seconds, the relay is pulled in, there is a signal, and the relay stops

P・24: After there is a signal for more than A seconds, the relay closes, and after the signal disappears for more than A seconds, the relay stops

P・25: After there is a signal for more than A seconds, the relay pulls in, and when there is another signal for more than A seconds, the relay stops

P・26: There is a signal that the relay pulls in for A second and stops, and the signal disappears and the relay pulls in again and stops after A second

P·27: When there is a pulse signal detected, the relay stops; if there is no pulse signal, the relay delays for A second to pick up; (the signal continues or the signal disappears, it is regarded as no pulse signal)

After P・2& is powered on, after a delay of A seconds, the relay will close until power off

P・31: After the power is turned on, the relay will be closed for A seconds and disconnected for B seconds, infinite loop; power off and stop

P・32: If there is a signal, start P・31 infinite loop; if the signal disappears, stop the loop

P・33: Give a signal to start the infinite loop of P.31; give a signal again to end the loop

P-34: After the power is turned on, after a delay of A seconds, the relay pulls in, and stops after pulling in B seconds

P・35: There is a signal, after a delay of A seconds, the relay will pick up, and it will stop after picking up for B seconds

P・36: There is a signal, after A seconds, the relay will be closed, and it will stop after B seconds, the signal disappears, and the timer is cleared and stopped

P・37: If there is a signal, the relay will automatically stop for A second, and it will count B seconds after it stops. If the signal is triggered within the A+B time, the signal will be invalid. Then, pull in again and automatically stop for A second. P·41: No action when there is a signal; trigger when the signal disappears; disconnect after the output start delay A time

P·42: The signal disappears, after the delay time A, the auxiliary output starts; the working time B ends

P-43: After the signal disappears for more than the A time, the output starts; the work B time ends

P-44: After the power is turned on, the output starts A time, and stops B time; the cycle C times automatically stops.

P·45: No action after power-on, after the signal is given; output start A time, stop B time; cycle C times and automatically stop; give the signal again, execute again

P-46: After the signal is given more than A times, the output starts; the output is maintained; the power off stops

P・47: After the signal is given more than A times, the output starts and stops for B seconds

P・4&In C seconds, after continuously giving the signal more than A times, the output starts and stops for B seconds

Welcome to our shop, enjoy the shipping here, you can contact with me freely if any question, usually we will send datasheet,code via email . hope to do business with you

payment:
we only accept the payment by credit card,western union.
We apologize that we cannot accept other payment methods, such as cheque or postal orders .
Shipping:
  1. We Ship to Worldwide, but Italy, Nigeria, Brazil will take long delivery time .

  2. Before buying, Please make sure your address is correct. Or not, please correct it before payment

  3. Ship to worldwide from Hong Kong within 12-24 hours after payment completed received, and will give you the tracking numberasap. sometimes we will send it by flat post air mail if just one low price order.Hope you understand.

  4. we advise shipping by DHL or EMS,and we have gave a discount for you,you can received it in 4-9 business days.

  5. it takes about 15-30days usually if shipping by CHina/Hong Kong post air mail

Feedback:
the feedback is very important for us, pls leave me a 5 stars feedback if you are satisfied with our service and our items,or pls contact with me if there are some problem with our items.we will solve it asap.
Warranty and Return:
  1. 12-months Warranty for defective items (excluding items damaged and/or misused after receipt).

Buy with confidence
  1. Refund or replacement request is available only the requests within 1 week after parcel received & returning the item as the same condition as received.

  2. Please contact us to request a return authorization. Your name, auction number, and reason for return should be included in the email. All items returned must contain all original packaging materials.

  3. Please repack the item carefully. Items returned will be tested and a new replacement will be shipped to the buyer immediately when found defective. In the event that a suitable replacement is not available then a refund will be issued. Shipping, handling and insurance fees are non refundable.

  4. Return shipping is to be paid by the Buyer.

ABOUT US:
we have much more products, pls contact us if you need.welcome to wholesale. MUCH THANKS!!

Specification

Dissipation Power : new

Model Number : new

Application : Computer

Condition : New

Supply Voltage : new

Brand Name : EMDSXGO

Origin : Mainland China

Type : Voltage Regulator

Operating Temperature : new

is_customized : Yes

+